On-site reading and programming
All stored information can
be retrieved on the WACO display directly on site. The individualized
direct programming allows almost any desired measurement.
Numeric tables and graphical
presentation
Very often graphical patterns will quickly indicate
the existence and the nature of a problem. Data can therefore
be retrieved not only in the form of numeric tables, but
also in a graphical format, to display the curves and patterns
present.
Easy to operate
The user-friendly on-screen menu guidance and comprehensive
help program allow an unproblematic operation of the WACO.
Flow, pressure and other
measurements
The logger measures and stores flow, pressures and other
data; i.e. level, temperature, pH etc. The logging intervals
are freely programmable and all the measured values are
stored in the large WACO memory. Moreover, the WACO always
also processes automatically statistical computation: Daily
totals, hourly totals, minima, maxima etc. And, of course,
current values can also be measured and displayed at any
moment.
Automatic leak analysis
Like all the earlier WACO models, the WACO 5000 also
offers the popular and proven leak analysis, automatically
indicating the presence of a leak and computing its volume
in m3/h.
Step testing
WACO 5000 is the only data logger offering a special
program for step testing - based either on flow or pressure
measurements. This method is used more and more for preliminary
leak location.
Impermeability testing
A further novelty is the built-in special program for
testing the impermeability of new pipes and sewers, either
by means of water or air. The measurement protocols show
the graphic curve of the drop of pressure as well as exceeding
preset levels.
Four different meters simultaneously
The WACO 5000 can accommodate 4 different meters simultaneously.
Each measuring input can be individually programmed as a
pulse or analogue entry. The programming allows separate
memorization or balancing of different entries (including
combination or bi-directional meters).
Four different alarm and
regulating outputs
Each entry can also simultaneously emit signals. Therefore
four different tasks can be programmed, in case the measuring
values exceed or do not reach preset levels, i.e. alert
messages open or close valves, or activate another external
process.
Large data memory
The 512 kB memory allows over 220,000 measurement values
to be stored.
Data output via Display,
Printer, PC, Modem or Radio
The possibilities of data output are unlimited. All
the data can be displayed on screen as numeric tables and
graphical presentations; they can also be directly printed
out on a printer or be downloaded to a PC. Data transfer
via modem or radio is also possible.
 |
Technical Specifications
Casing
material: |
Aluminium |
Dimensions: |
220
x 120 x 90 mm (8.6" x 4.7" x
3.5") |
Weight: |
1.5
kg (3.3 lb.) |
Protection: |
IP
67 |
Signal
Input: |
4
entries, individually programmable as
pulse or analogue |
Signal
Output: |
4
signal outputs |
Data
Output: |
RS
232C interface |
Display: |
LCD
display 38 x 132 mm (1.5" x 5.2")
with back light. |
Key
pad: |
Waterproof
touch key pad with 8 keys |
Memory
capacity: |
512
kB for over 220,000 measurement values |
Power
supply: |
5
"C" type 1.5V alkaline batteries
(LR14). Battery life: up to 1-2 years,
according to use. |
Data
back-up: |
Memory
back-up battery |
Temperature
range: |
-10°C
to +50°C (14°F to 122°F) |
Measurement
accuracy: |
0.1% |
Logging
interval: |
freely
programmable |
|
|